XG-10M-3 Plastic Pipe Hydrostatic Pressure Tester(Dual circuit)
Plastic Pipe Hydrostatic Pressure Tester is suitable for testing the instantaneous hydraulic burst of various plastic pipes used for fluid transportation and the failure resistance of thermoplastic pipes under long-term constant pressure. It is an essential testing instrument for research institutes, quality inspection departments, and pipe manufacturers.
The hydrostatic tester utilizes computer-embedded control. Its modular design enables individual control. If a problem occurs in any line, simply closing the shutoff valve at the current station will not affect the normal operation of other stations. It features functions such as pipe rupture detection, real-time monitoring, call data recovery, test result printing, storage, and sample pre-processing settings. To accommodate national holidays, it can store up to seven days of data.
Standard Compliance:
|
Standard No. |
Standard Name |
|
GB/T6111-2018 |
Test method for the internal pressure resistance of thermoplastic pipes for the transportation of liquids |
|
GB/T15560-1995 |
Test method for the hydraulic transient burst and pressure resistance of plastic pipes for the transportation of fluids |
|
GB/T18252-2008 |
Determination of the long-term hydrostatic strength of thermoplastic pipes for plastic piping systems by the extrapolation method |
|
ASTM D1598-2004 |
Pipe, Plastic, Under Constant Internal Pressure, Time-to-Failure of (No S/S Document) |
|
ASTMD1599 |
Standard Test Method for Resistance to Short-Time Hydraulic Pressure of Plastic Pipe, Tubing, and Fittings |
|
ASTM D1599 |
Standard Test Method forResistance to Short-Time Hydraulic Pressure of PlasticPipe, Tubing, and Fittings1 |
|
GB/T18476-2001 |
Polyolefin pipes for conveying fluids - Determination of resistance to crack growth - Test method for slow crack growth in notched pipes (notch test) |
|
ISO1167 |
Thermoplastic pipes, fittings, and assemblies for conveying fluids - Determination of resistance to internal pressure |
|
ISO13479 |
Determination of resistance of polyolefin pipes for the conveyance of fluids to crack propagation |
|
ISO9080 |
Plastics piping and ducting systems - Determination of the long-term hydrostatic strength of thermoplastics materials in pipe form by extrapolation (ISO9080, Ed. 1.0 (2003) MOD) |
|
DIN EN 921 (1995-01) |
Thermoplastics pipes - Determination of resistance to internal pressure at constant temperature |

Instrument Features
Control System:
Two-Level Monitoring
The first level provides 1-hour, detailed monitoring; the second level provides comprehensive, full-process monitoring. Equipped with a computer and printer, the instrument offers functions such as leak detection, rupture identification, real-time monitoring, power-off pressure maintenance, power-off data storage, call-in data recovery, test result printing and storage, and automatic pressure formula calculation. The graph display is synchronized with the actual test time. Ø
Multi-Purpose Unit
It can perform both long-term hydrostatic testing of pipelines and burst testing of pipes (each circuit can perform both burst and pressure tests). It can also be used for thermal stability testing of thermoplastic pipes under hydrostatic conditions. Each circuit features multi-stage accumulator pressure control, ensuring fast response and stable pressure control, extending the service life of the solenoid valve.
Dual-Pipe Circuit Structure
Traditional hydrostatic testing machines for pipes use a pressure supply to a boost valve, where pressure is collected, and then transmitted to the specimen. The other end is connected to a pressure relief valve, eliminating any backflow and creating a pressure differential between the specimen and the sensor. Our product utilizes a novel design: the pressure control system utilizes a dual-circuit structure with independent pressure supply and pressure collection. This means that two pipes connect the pressure unit to the specimen: one is a boost pipe for both boosting and releasing pressure, and the other is used to measure specimen pressure, with pressure taken directly from the specimen inlet.
Technical Parameters
|
XG-10M-3 Plastic Pipe Hydrostatic Pressure Tester(Dual circuit) |
||
|
Tester Accuracy Level |
0.5 level |
|
|
Maximum Test Pressure |
10MPa |
|
|
Number of Test Paths |
3-channel |
|
|
Control Method |
Industrial touch screen computer control |
|
|
Data Storage |
Each channel has power-off data protection and can be restored upon restart |
|
|
Time |
Timing time |
0 to 9999 hours and 59 minutes |
|
Timing accuracy |
±0.1% |
|
|
Time resolution |
1 second |
|
|
Minimum setting unit |
min |
|
|
Pressure |
Pressure control range |
0.2 to 10 MPa |
|
Pressure display unit |
MPa, bar, or PSI |
|
|
Pressure control accuracy |
-1% to +2% |
|
|
Full-load constant pressure control accuracy |
Within ±0.3% |
|
|
Pressure display resolution |
0.001 MPa, 0.01 bar, or 1 PSI |
|
|
Measurement range |
0-100% FS |
|
|
Indication error limit |
Within ±1% of displayed value |
|
|
Range |
Sample tube diameter |
Ø16mm-Ø400mm |



Other Related Machine


Impact testing machine Tensile Testing Machine
Hot Tags: plastic pipe hydrostatic pressure tester, China plastic pipe hydrostatic pressure tester manufacturers, factory