This European standard specifies the three-point bending test method to measure bending modulus of elasticity (MOE) and bending strength (MOR) for all wood-based panels (particleboard, MDF, OSB, plywood, cement-bonded particleboard, etc.) with nominal thickness ≥ 3 mm.
1.Normative references
EN 326-1: Wood-based panels – Sampling, cutting and conditioning of test specimens
EN 322: Wood-based panels – Determination of moisture content
EN 323: Wood-based panels – Determination of density
2.Apparatus
Universal testing machine (UTM): Force accuracy ≤ ±1 % full scale; continuous uniform speed control.
Three-point bending fixture:
Two cylindrical supports, one cylindrical loading head; all cylinders have identical diameter.
Standard cylinder diameter: 15 mm; for panels thicker than 25 mm, diameter can be increased appropriately.
Linear displacement sensor / extensometer: For deflection measurement (required for MOE calculation).
Caliper: Accuracy 0.01 mm, to measure specimen actual length, width, thickness.
3.Specimen preparation
4.1 Sampling & cutting
Follow EN 326-1 to cut specimens from test panels; no visible defects (cracks, knots, delamination) on specimens.Specimen width (b)50mm
5 Test setup installation
Place two parallel cylindrical supports horizontally, set span length strictly as calculated above.
Centre the specimen flat on the two supports, ensure the specimen is perpendicular to support axes.
Install the central loading head right above the midpoint of the span.
Mount deflection measuring device at specimen mid-span to record mid-span deflection accurately.
6 Test execution
Set constant loading speed: Crosshead speed = 0.10 × span length per minute Example: Span L=180 mm → speed = 18 mm/min
Apply load continuously and smoothly without impact or vibration.
Record data synchronously: load value F and mid-span deflection w throughout loading.
Continue loading until specimen breaks; record the maximum breaking load
For MOE calculation: select the linear elastic segment of load-deflection curve (linear proportional range only).
Measure actual specimen thickness t, actual width b immediately after fracture.