Tensile testing machine is also called universal material testing machine or tensile machine, the use of electromechanical integration design, by the main part, mechanical part, hydraulic system, force measurement system, etc., the force measurement system is mainly composed of force sensors, transmitters, microprocessors, load driving mechanism, computer and color inkjet printer. This small series will introduce the performance and use precautions of the tensile testing machine.
Tensile testing machine performance
1. The control software can actively obtain test data such as tensile strength, yield strength, breaking strength, elastic modulus, elongation, etc., and the open formula modification can actively calculate the force, stress, displacement, deformation and other data results at any specified point in the experiment process. The control and data processing of the experimental process meet the requirements of the corresponding national standards for metal data and non-metal data.
2. Control method: fixed speed, positioning, fixed load, fixed load increase rate, fixed stress, fixed stress increase rate, fixed strain, fixed strain increase rate and other control methods are optional;
3. Active zero clearing: After the start of the experiment, the measurement system actively adjusts to zero;
4. Active shift: according to the load size of the active switch to the appropriate range, to ensure the accuracy of measurement data;
5. Active storage: active storage of experimental data and experimental conditions to prevent data loss caused by forgetting the storage;
6. Batch experiment: for the samples with the same parameters, a batch of experiments can be completed successively after one setting;
7. Display method: data and curves are displayed dynamically with the process of the experiment;
8. Curve traversal: After the experiment is completed, the curve can be re-analyzed and the data corresponding to each point on the experimental curve can be found with the mouse;
9. Curve selection: stress-strain, force-displacement, force-time, displacement-time and other curves can be selected for display and printing;
10. Experimental report: The experimental report can be programmed and printed according to the pattern of user needs, and can be exported to EXCEL files.
Notes on the use of tensile testing machine
1, at the time of boot, the boot order of the host and the computer will affect the communication initialization Settings of the computer, so it must be strictly carried out in accordance with the above boot order.
2, after the boot need to preheat for 5 minutes, such as the system is stable, can be tested.
3, if you need to start again after just starting, wait at least 1 minute interval time.
4. After replacing the fixture, first pay attention to adjusting the adjustable stop ring.
5, when using the small force value sensor to do the experiment, be sure to adjust the position of the adjustable stop ring, to avoid damage to the small force value sensor due to operational error, be careful not to exceed the rated range of the sensor.
6, be careful not to plug and unplug the power cord, otherwise it will easily damage the electrical control part.
7, do not stay away from the testing machine during the test.
8, during the test process, in addition to the stop button and the emergency stop switch, do not press the other keys above the control box to avoid affecting the test.
9. Remember to turn off all power after the test.
10, the computer is specially used for data processing and testing machine control, do not install other application software in it, to avoid the normal operation of the testing machine application software.
11. Strictly launch the computer step by step according to the system requirements, and then shut down normally to avoid damaging some programs, resulting in the normal use of the software
12. Do not use floppy disks unrelated to the machine to read or write disks on the computer of the testing machine to avoid virus infection.